Article title PERSONAL AND PATIENT SAFETY WHEN USING MEDICAL ELECTRIC EQUIPMENT
Authors L. M. Vedeneyeva, K. A. Chernyi
Section SECTION II. METHODS AND DEVICES IN MEDICAL AND BIOLOGICAL PRACTICE
Month, Year 06, 2018 @en
Index UDC [614.825 + 331.45]:615.47
DOI
Abstract The use of medical electrical equipment and devices that allow for the implementation of modern methods of examination and treatment urgently require improved requirements to ensure the safety of patients and medical personnel. The aim of the work is to analyze the electrical safety of staff and patients in a medical institution and the reliability of medical electrical equipment. As is well known, a complex of protective measures against electric shock for a medical institution is determined taking into account the type of building power supply system, the class of medical equipment according to the degree of protection against electrical shock, the class of the medical room. When designing grounding devices for medical institutions, consideration should be given to all factors that may affect the effectiveness of protection and reliability of complex medical electrical equipment. The conductivity of soils is one of the most important of these factors and depends on the type, porosity (the ability of the rock to contain liquids and gases) and the structure of the soil, the degree of its humidity, temperature, degree of compaction, time of year, etc. The results of the study of the effect of the conductivity of soils on the values of their specific electrical resistance and, consequently, the resistance of grounding devices, which determine the safety of operation of medical electrical equipment, are presented. It is shown that the specific electrical resistance varies over wide ranges depending on different values of the porosity of the soil: for large values of the porosity of the soil, its specific electrical resistance decreases dramatically, since the pores can be filled with liquid, while increasing the conductivity of the soil. The calculation results are presented in the form of graphical dependences of the soil resistivity on the value of its porosity. So for sand it is shown that the limits of change of electrical resistance depending on its porosity, i.e. depending on the density of its installation, may vary by more than seventeen times. Based on the research conducted, it is reasonable that when designing grounding devices in medical institutions, it is necessary to take into account the porosity of soils in order to reduce the actual values of the resistances of grounding devices.

Download PDF

Keywords Safety; medical electrical equipment; grounding; the specific electrical resistance of the soil; the porosity of the soil; the conductivity of the soil.
References 1. Livenson A.R. Elektrobezopasnost' meditsinskoy tekhniki [Electrical safety of medical equipment]. Issue 1. Moscow: Meditsina, 1975, 165 p.
2. Gertsik Yu.G. Tekhnika bezopasnosti pri klinicheskoy ekspluatatsii elektromeditsinskikh izdeliy [Safety in clinical use of electromedical products]. Moscow: Izd-vo MGTU im.
N.E. Baumana, 2017, 64 p.
3. Colella P., Pons E., Tommasini R. Dangerous touch voltages in buildings: The impact of extraneous conductive parts in risk mitigation, Electric Power Systems Research, 2017, Vol. 147, pp. 263-271.
4. GOST R 50571.28-2006. Elektroustanovki zdaniy [Electrical installation of buildings]. Part 7-710. Trebovaniya k spetsial'nym elektroustanovkam. Elektroustanovki meditsinskikh pomeshcheniy [Requirements for special electrical installations. Electrical installations of medical facilities].
5. Vedeneeva L.M., CHudinov A.V. Issledovanie vliyaniya osnovnykh svoystv grunta na soprotivlenie zazemlyayushchikh ustroystv [Investigation of the influence of the basic properties of soil on the resistance of grounding devices], Vestnik Permskogo natsional'nogo issledovatel'skogo politekhnicheskogo universiteta. Geologiya. Neftegazovoe i gornoe delo [Bulletin of the Perm national research Polytechnic University. Geology. Oil and gas and mining], 2017, Vol. 16, No. 1, ppS. 89-100.
6. Zhou M., Wang J., Cai L., Fan Y. Laboratory investigations on factors affecting soil electrical resistivity and the measurement, IEEE Transactions on Industry Applications, 2015,
Art. No. 7182309.
7. Malanda S.C., Davidson I.E., Singh E., Buraimoh E. Analysis of Soil Resistivity and its Impact on Grounding Systems Design, IEEE Power and Energy Society and Industrial Applications Society PowerAfrica, 26–29 June 2018, Cape Town, South Africa. Cape Town: 2018, Art. No. 8520960, pp. 324-329.
8. Konsul'tatsii po geologii. Poristost' gruntov [Consultations on Geology. The porosity of soils]. Available at: http://sprosigeologa.ru/opredelenie-svoystv-gruntov/poristost-grunta/ (accessed 26 October 2018).
9. Coelho Vilson Luiz, Piantini Alexandre, Almaguer Hugo A.D., Coelho Rafael A., Boaventura Wallace do C., Paulino Jose Osvaldo S. The influence of seasonal soil moisture on the behavior of soil resistivity and power distribution grounding systems, In The Lightning Flash and Lightning Protection (SIPDA 2013), Electric Power Systems Research, 2015, Vol. 118, pp. 76-82.
10. Fuji-ta K., Seki M., Ichiki M. Random network model of electrical conduction in two-phase rock, Mineralogy and Petrology, 2018, Vol. 112, Issue 6, pp. 857-864.
11. Wei Bai, Lingwei Kong, Aiguo Guo. Effects of physical properties on electrical conductivity of compacted lateritic soil, Journal of Rock Mechanics and Geotechnical Engineering, 2013,
No. 5, Issue 5, pp. 406-411.
12. Tung C.C., Lim S.C. Performance of electrical grounding system in soil at low moisture content condition at various compression levels, Journal of Engineering Science and Technology, 2017, Vol. 12, Special Issue 1, pp. 27-47.
13. Yavleniya, voznikayushchie pri zamykanii na zemlyu [The phenomena occurring when short to ground], Elektrotekhnicheskiy portal [Electrical engineering portal]. Available at: http://xn----8sbnaarbiedfksmiphlmncm1d9b0i.xn--p1ai/bezgd/r5-gl52/64-yavlenia-pri-zamikanii-na-zemly.html (accessed 26 October 2018).
14. Dolin P.A. Osnovy tekhniki bezopasnosti v elektroustanovkakh: ucheb. posobie dlya vuzov [Basics of safety in electrical installations: a textbook for universities]. Moscow: Energoatomizdat, 1984, 448.
15. Karyakin R.N. Zazemlyayushchie ustroystva elektroustanovok: spravochnik [Grounding devices of electrical installations: reference]. Moscow: Energoservis, 2006, 523 p.
16. Nazarov N.N. Geografiya Permskogo kraya [Geography of Perm region]. Part 1. Prirodnaya (fizicheskaya) geografiya: ucheb. posobie [Natural (physical) geography: textbook]. Perm', 2006, 139 p.
17. Vlasov M.N. Uchebnaya praktika po pochvovedeniyu: ucheb.-metod. Posobie [Educational practice in soil science: teaching manual]. Perm': Perm. gos. sel'skokhoz. akademiya, 2013, 122 p.
18. Karta pochv Permskogo kraya [Soil map of the Perm region]. Available at: http://gnilomedova.59313s016.edusite.ru/p7aa1.html (accessed 26 October 2018).
19. Vedeneeva L.M., Chudinov A.V. Uchet neodnorodnosti grunta pri proektirovanii zazemlyayushchikh ustroystv v razlichnykh regionakh Permskogo kraya [Taking into account the heterogeneity of soil in the design of grounding devices in different regions of the Perm region], Vestnik Permskogo natsional'nogo issledovatel'skogo politekhnicheskogo universiteta. Elektrotekhnika [Bulletin of the Perm national research Polytechnic University. Electrical engineering], 2016, No. 2, pp. 136-152.
20. OFiPS. KHarakteristiki plotnosti gruntov i plotnosti ikh slozheniya [Ofips. Characteristics of soil density and density of their addition]. Available at: http://xn--h1aleim.xn--p1ai/sorochan/g1-2.html (accessed 26 October 2018).
21. Tyumenskiy gosudarstvennyy neftegazovyy universitet. Fizicheskie kharakteristiki gruntov [Tyumen state oil and gas University. Physical characteristics of soils]. Available at: http://www.studfiles.ru/preview/5333520/page:2/ (accessed 26 October 2018).
22. Mohamed Ahmed Khalil, Fernando A. Monterio Santos. Influence of Degree of Saturation in the Electric Resistivity–Hydraulic Conductivity Relationship, Surveys in Geophysics, 2009, Vol. 30, pp. 601-615.

Comments are closed.